Loading...
 

WMA100F

Key Product Features

・For medical electric equipment
(ANSI/AAMI ES60601-1, EN60601-1 3rd)
・Medical Isolation Grade 2MOPP
・4kV isolation
・Low-profile
・Economical design

Technical Features

  • Leakage Current <0.5mA

Options

(For detailed information, please refer to the instruction manual)

WM(1) A(2) 100(3) F(4) - (5) - (6) 


(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
C:With Coating
G:Low leakage current
J1:VH(J.S.T.)connector type
J4:EP(Tyco)connector type
T1:Horizontal terminal block
See 5.1 in Instruction Manual.
string(493) "

WM(1) A(2) 100(3) F(4) - (5) - (6) 


(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
C:With Coating
G:Low leakage current
J1:VH(J.S.T.)connector type
J4:EP(Tyco)connector type
T1:Horizontal terminal block
See 5.1 in Instruction Manual."

Product Data

  • Datasheet
  • Instruction Manual
  • Glossary of Technical Terms

Drawings

  • CAD Data (DXF)
  • 3D CAD Data (STEP)
    • Standard model
  • 3D CAD Data (IGES)
    • Standard model

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity

WM(1) A(2) 100(3) F(4) - (5) - (6) 


(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
C:With Coating
G:Low leakage current
J1:VH(J.S.T.)connector type
J4:EP(Tyco)connector type
T1:Horizontal terminal block
See 5.1 in Instruction Manual.
Basic Specification WMA100F-12 WMA100F-24 WMA100F-48
  Check Stock Check Stock Check Stock
Input Voltage Range AC85 ~ 264V 1Φ
Output Voltage / Current 12V 8.4A 24V 4.3A 48V 2.1A
Output Power 100.8W 103.2W 100.8W
Output Voltage Adj Range Refer to datasheet
Operating Temp (°C) -20 to +70℃ (Required to Derating) , 20 - 90%RH (Non condensing)
Cooling Method Convection
Dimensions (W x H x D) 30×97×129mm
Safety Agency Approvals UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, ANSI/AAMI ES60601-1, C-UL (equivalent
to CAN/CSA-C22.2 No.60601-1), EN60601-1 3rd, EN61558-2-16 (OVC III), Complies with IEC60601-1-2 4th Ed.
Technical Data WMA100F-12 WMA100F-24 WMA100F-48
Performance Data
EMC Data
Expected Life
MTBF
Reliability Data