Loading...
 

LDA100W

Discontinued

Options

(For detailed information, please refer to the instruction manual)

  C: with Coating
  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option.
string(603) "

LDA(1)  100(2)  W(3)  -  5(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Autoranging input
(4) Output voltage
(5) Optional*
  C: with Coating
  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option."

Product Data

  • Datasheet
  • Instruction Manual
  • Accessories
  • Glossary of Technical Terms

Drawings

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity
  • UK Declaration of Conformity

LDA(1)  100(2)  W(3)  -  5(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Autoranging input
(4) Output voltage
(5) Optional*
  C: with Coating
  G: Low leakage current
  R: with Remote ON/OFF
  S: with Chassis
  SN: with Chassis & cover
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option.
Basic Specification LDA100W-3 LDA100W-5 LDA100W-9 LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24 LDA100W-24-H LDA100W-30 LDA100W-48
  Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock
Input Voltage Range AC85 - 132V/170 - 264V 1Φ AC85 - 132V/170 - 264V 1Φ AC85 - 132V/170 - 264V 1Φ AC85 - 132V/170 - 264V 1Φ
Output Voltage / Current 3V 20A 5V 20A 9V 11.5A 12V 8.5A 15V 6.7A 18V 5.6A 24V 4.3A 24V 4.3A (Peak: 6.5A) 30V 3.5A 48V 2.0A
Output Power 60W 100W 103.5W 102W 100.5W 100.8W 103.2W 105W 96W
Output Voltage Adj Range 2.85 - 3.6V 4.5 - 5.5V Refer to datasheet Refer to datasheet Refer to datasheet
Operating Temp (°C) -10 to +60℃, 20 - 90%RH (Non condensing) * -10 to +60℃, 20 - 90%RH (Non condensing) * -10 to +60℃, 20 - 90%RH (Non condensing) * -10 to +60℃, 20 - 90%RH (Non condensing) *
Cooling Method Convection Convection Convection Convection
Dimensions (W x H x D) 62x35x222mm 62x35x222mm 62x35x222mm 62x35x222mm
Safety Agency Approvals UL60950-1, CSA C22.2 No.234, EN62368-1 Complies with DEN-AN and IEC60950-1 UL60950-1, CSA C22.2 No.234, EN62368-1 Complies with DEN-AN and IEC60950-1 UL60950-1, CSA C22.2 No.234, EN62368-1 Complies with DEN-AN and IEC60950-1 UL60950-1, CSA C22.2 No.234, EN62368-1 Complies with DEN-AN and IEC60950-1
Technical Data LDA100W-3 LDA100W-5 LDA100W-9 LDA100W-12 LDA100W-15 LDA100W-18 LDA100W-24 LDA100W-24-H LDA100W-30 LDA100W-48
Performance Data
EMC Data On request
Expected Life N/A N/A N/A N/A N/A N/A
MTBF On request
Reliability Data