Loading...
 

SUS

Status
Open
Name
SUS
Brand
Cosel
Input Type
DC-DC
Isolated
Case Style
Open Frame
Cooling Method
Convection
Mounting Method
PCB Mount
Surface Mount
Through-Hole
Output Type
Single
Output Voltages
3.3V, 5V, 12V, 15V
Input Voltages
Technical Features
  • < 1U High
Related Products
Main Image
SusseriesLarge
Industry
  • Industrial
Features
  • Low Power DC-DC Converter
  • Operating Temperature (-40 to +85 °C)
  • Various Input/Output Combinations
  • Built in Remote On/Off
  • 5 Year Warranty
  • EN & UL Approved

Additional Technical Documents
 
Part Number Configurator
Keywords
AC Input Voltage Min
AC Input Voltage Max
DC Input Voltage Min
4.50
DC Input Voltage Max
76.00
Output Voltage Min
3.30
Output Voltage Max
15.00
Output Current Min
0.10
Output Current Max
2.60
Output Power Min
1.32
Output Power Max
12.00
Series Webservice

Data

{
    "name": "SUS",
    "pic_path": "\/tool\/tag\/pic\/sus.jpg",
    "product_system_str": "PCB Mount type",
    "environment_mark_str": "RoHS, eco",
    "explanation": "Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage: 1.5 - 10W",
    "patent": "\u2022 SMD mounting type and through-hole mounting type<br \/>\u2022 High efficiency (synchronous rectifier circuit)<br \/>\u2022 Built-in overcurrent protection circuits<br \/>\u2022 Built-in remote ON\/OFF (SU\/SUC 3, 6, 10)<br \/>\u2022 High reliability: not built-in aluminum and tantalum electrolytic capacitor",
    "free_guarantee_term_unit": "-year",
    "free_guarantee_term_specification": "5"
}

Mapping

{
    "power_series": {
        "name": {
            "type": "sortable",
            "field": "title"
        },
        "pic_path": {
            "type": "plaintext",
            "field": "cs_pic_path"
        },
        "explanation": {
            "type": "plaintext",
            "field": "description"
        },
        "patent": {
            "type": "plaintext",
            "field": "cs_patent"
        },
        "product_system_str": {
            "type": "plaintext",
            "field": "cs_product_system"
        },
        "environment_mark_str": {
            "type": "plaintext",
            "field": "cs_environment_mark"
        },
        "free_guarantee_term_unit": {
            "type": "plaintext",
            "field": "cs_free_guarantee_term_unit"
        },
        "free_guarantee_term_specification": {
            "type": "plaintext",
            "field": "cs_free_guarantee_term_specification"
        },
        "note": {
            "type": "plaintext",
            "field": "cs_note"
        }
    }
}
Models Webservice

Data

[
    {
        "name": "SUS1R5",
        "pic_path": "\/tool\/tag\/pic\/sus1r5.jpg",
        "cool_str": "Convection Cooling",
        "explanation": "Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage: 1.5W<br \/>Rated Output Voltage: 3.3V,5V,12V,15V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_SU.pdf",
        "struct_cool": "Convection\/Forced air"
    },
    {
        "name": "SUS3",
        "pic_path": "\/tool\/tag\/pic\/sus3.jpg",
        "cool_str": "Convection Cooling",
        "explanation": "Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage: 3W<br \/>Rated Output Voltage: 3.3V,5V,12V,15V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_SU.pdf",
        "struct_cool": "Convection\/Forced air"
    },
    {
        "name": "SUS6",
        "pic_path": "\/tool\/tag\/pic\/sus6.jpg",
        "cool_str": "Convection Cooling",
        "explanation": "Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage: 6W<br \/>Rated Output Voltage: 3.3V,5V,12V,15V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_SU.pdf",
        "struct_cool": "Convection\/Forced air"
    },
    {
        "name": "SUS10",
        "pic_path": "\/tool\/tag\/pic\/sus10.jpg",
        "cool_str": "Convection Cooling",
        "explanation": "Rated Input: DC4.5 - 9V, DC9 - 18V, DC18 - 36V, DC36 - 76V<br \/>Rated Output Wattage: 10W<br \/>Rated Output Voltage: 3.3V,5V,12V,15V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_SU.pdf",
        "struct_cool": "Convection\/Forced air"
    }
]

Mapping

{
    "power_models": [
        {
            "name": {
                "type": "sortable",
                "field": "title"
            },
            "pic_path": {
                "type": "plaintext",
                "field": "csm_pic_path"
            },
            "explanation": {
                "type": "wikitext",
                "field": "description"
            },
            "cool_str": {
                "type": "wikitext",
                "field": "csm_cool_str"
            },
            "struct_cool": {
                "type": "wikitext",
                "field": "csm_struct_cool"
            },
            "catalog_pdf": {
                "type": "plaintext",
                "field": "csm_ catalog_pdf"
            }
        }
    ]
}
Market Status
Active
Market Status Text
Market Status Sort Order
d