Loading...
 

GHA

Status
Open
Name
GHA
Brand
Cosel
Input Type
AC-DC
Case Style
Enclosed
Open Frame
Cooling Method
Conduction
Convection
Forced Air
Mounting Method
Chassis Mount
Output Type
Single
Output Voltages
12V, 15V, 24V, 30V, 48V, 56V
Input Voltages
Technical Features
  • Remote On/Off
  • Alarm
  • Parallel Function
  • Leakage Current <0.5mA
  • < 1U High
Related Products
Main Image
GhaseriesLarge
Industry
  • Medical
  • Energy
  • Industrial
  • Communication
Features
  • 3 x 5 Medical/Industrial Power Supply
  • 2 x MOPP for Medical Applications
  • Conduction cooling (500W)
  • AUX (5V/12V), Remote On/Off, Alarm
  • 5 Year Warranty
  • EN & UL Approved

Additional Technical Documents
 
Part Number Configurator
Keywords
AC Input Voltage Min
90.00
AC Input Voltage Max
264.00
DC Input Voltage Min
DC Input Voltage Max
Output Voltage Min
10.80
Output Voltage Max
56.00
Output Current Min
0.00
Output Current Max
37.50
Output Power Min
300.00
Output Power Max
700.00
Series Webservice

Data

{
    "name": "GHA",
    "pic_path": "\/tool\/tag\/pic\/gha2.jpg",
    "product_system_str": "Open Frame type",
    "environment_mark_str": "RoHS, eco",
    "explanation": "Rated Input: AC90 - 264V 1&Phi;<br \/>GHA700F AC85 - 264V 1&Phi;<br \/>Rated Output Wattage: 300 - 700W",
    "patent": "\u2022 Wattage 700W max<br \/>\u2022 Conduction cooling (GHA500F, GHA700F)<br \/>\u2022 3\"X5\"standard footprint<br \/>\u2022 Less than 1U high<br \/>\u2022 ITE and Medical safety approvals<br \/>\u2022 Low leakage current<br \/>\u2022 Suitable for BF application (Output-FG: 1MOPP, Input-Output: 2MOPP) (GHA700F)<br \/>\u2022 With Remote (Option)<br \/>\u2022 With AUX1 (12V) (Optional Excludeing GHA700F-12)<br \/>\u2022 With AUX2 (5V) (Optional)<br \/>",
    "note": "This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, please handle the unit with care<br \/>*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC\/EMI regulations.",
    "free_guarantee_term_unit": "-year (Refer to Instruction Manuals)",
    "free_guarantee_term_specification": "5"
}

Mapping

{
    "power_series": {
        "name": {
            "type": "sortable",
            "field": "title"
        },
        "pic_path": {
            "type": "plaintext",
            "field": "cs_pic_path"
        },
        "explanation": {
            "type": "plaintext",
            "field": "description"
        },
        "patent": {
            "type": "plaintext",
            "field": "cs_patent"
        },
        "product_system_str": {
            "type": "plaintext",
            "field": "cs_product_system"
        },
        "environment_mark_str": {
            "type": "plaintext",
            "field": "cs_environment_mark"
        },
        "free_guarantee_term_unit": {
            "type": "plaintext",
            "field": "cs_free_guarantee_term_unit"
        },
        "free_guarantee_term_specification": {
            "type": "plaintext",
            "field": "cs_free_guarantee_term_specification"
        },
        "note": {
            "type": "plaintext",
            "field": "cs_note"
        }
    }
}
Models Webservice

Data

[
    {
        "name": "GHA300F",
        "pic_path": "\/tool\/tag\/pic\/gha300f.jpg",
        "cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling, Conduction Cooling",
        "explanation": "Rated Input: AC90 - 264V 1&Phi;<br \/>Rated Output Wattage: 300W<br \/>Rated Output Voltage: 12V,24V,48V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_GHA.pdf",
        "struct_cool": "Convection, Forced air (Require external fan)"
    },
    {
        "name": "GHA500F",
        "pic_path": "\/tool\/tag\/pic\/gha500f.jpg",
        "cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling, Conduction Cooling",
        "explanation": "Rated Input: AC90 - 264V 1&Phi;<br \/>Rated Output Wattage: 500W<br \/>Rated Output Voltage: 12V,15V,24V,30V,48V,56V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_GHA.pdf",
        "struct_cool": "Convection, Forced air (Require external fan) , Conduction cooling"
    },
    {
        "name": "GHA700F",
        "pic_path": "\/tool\/tag\/pic\/gha700f.jpg",
        "cool_str": "Forced Air (Require external fan) Cooling, Convection Cooling, Conduction Cooling",
        "explanation": "Rated Input: AC85 - 264V 1&Phi;<br \/>Rated Output Wattage: 700W<br \/>Rated Output Voltage: 12V, 24V, 30V, 48V, 56V",
        "catalog_pdf": "\/tool\/tag\/pdf\/SFE_GHA.pdf",
        "struct_cool": "Convection, Forced air (Require external fan) , Conduction cooling"
    }
]

Mapping

{
    "power_models": [
        {
            "name": {
                "type": "sortable",
                "field": "title"
            },
            "pic_path": {
                "type": "plaintext",
                "field": "csm_pic_path"
            },
            "explanation": {
                "type": "wikitext",
                "field": "description"
            },
            "cool_str": {
                "type": "wikitext",
                "field": "csm_cool_str"
            },
            "struct_cool": {
                "type": "wikitext",
                "field": "csm_struct_cool"
            },
            "catalog_pdf": {
                "type": "plaintext",
                "field": "csm_ catalog_pdf"
            }
        }
    ]
}
Market Status
New Models
Market Status Text
Market Status Sort Order
c