Loading...
 

SUTS6

NRND

Options

(For detailed information, please refer to the instruction manual)

  G: Capacitor between Input and Output is removed.
string(402) "

SUT(1)  S(2)  6(3)  12(4)  05(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
  G: Capacitor between Input and Output is removed."

Product Data

  • Datasheet
  • Instruction Manual
  • Glossary of Technical Terms

Drawings

  • CAD Data (DXF)
  • 3D CAD Data (STEP)
    • Standard model
  • 3D CAD Data (IGES)
    • Standard model

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity
  • UK Declaration of Conformity

SUT(1)  S(2)  6(3)  12(4)  05(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
  G: Capacitor between Input and Output is removed.
Basic Specification SUTS6053R3 SUTS60505 SUTS60512 SUTS60515 SUTS6123R3 SUTS61205 SUTS61212 SUTS61215 SUTS6243R3 SUTS62405 SUTS62412 SUTS62415 SUTS6483R3 SUTS64805 SUTS64812 SUTS64815
  Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock
Input Voltage Range DC4.5 - 9V DC4.5 - 9V DC9 - 18V DC9 - 18V DC18 - 36V DC18 - 36V DC36 - 76V DC36 - 76V
Output Voltage / Current 3.3V 1.2A 5V 1A 12V 0.5A 15V 0.4A 3.3V 1.35A 5V 1.2A 12V 0.5A 15V 0.4A 3.3V 1.35A 5V 1.2A 12V 0.5A 15V 0.4A 3.3V 1.35A 5V 1.2A 12V 0.5A 15V 0.4A
Output Power 3.96W 5W 6W 4.46W 6W 4.46W 6W 4.46W 6W
Output Voltage Adj Range Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet
Operating Temp (°C) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating)
Cooling Method Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air
Dimensions (W x H x D) 37.6x26.4x9.15mm 37.6x26.4x9.15mm 37.6x26.4x9.15mm 37.6x26.4x9.15mm 37.6x26.4x9.15mm 37.6x26.4x9.15mm
Safety Agency Approvals UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1
Technical Data SUTS6053R3 SUTS60505 SUTS60512 SUTS60515 SUTS6123R3 SUTS61205 SUTS61212 SUTS61215 SUTS6243R3 SUTS62405 SUTS62412 SUTS62415 SUTS6483R3 SUTS64805 SUTS64812 SUTS64815
Performance Data
EMC Data
Expected Life N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
MTBF
Reliability Data