Loading...
 

SUTS10

NRND

Options

(For detailed information, please refer to the instruction manual)

  G: Capacitor between Input and Output is removed.
string(403) "

SUT(1)  S(2)  10(3)  12(4)  05(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
  G: Capacitor between Input and Output is removed."

Product Data

  • Datasheet
  • Instruction Manual
  • Glossary of Technical Terms

Drawings

  • CAD Data (DXF)
  • 3D CAD Data (STEP)
    • Standard model
  • 3D CAD Data (IGES)
    • Standard model

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity
  • UK Declaration of Conformity

SUT(1)  S(2)  10(3)  12(4)  05(5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Input voltage
(5) Output voltage
(6) Optional
  G: Capacitor between Input and Output is removed.
Basic Specification SUTS10053R3 SUTS100505 SUTS100512 SUTS100515 SUTS10123R3 SUTS101205 SUTS101212 SUTS101215 SUTS10243R3 SUTS102405 SUTS102412 SUTS102415 SUTS10483R3 SUTS104805 SUTS104812 SUTS104815
  Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock
Input Voltage Range DC4.5 - 9V DC4.5 - 9V DC9 - 18V DC9 - 18V DC18 - 36V DC18 - 36V DC36 - 76V DC36 - 76V
Output Voltage / Current 3.3V 2.6A 5V 2A 12V 0.9A 15V 0.7A 3.3V 2.6A 5V 2A 12V 1A 15V 0.8A 3.3V 2.6A 5V 2A 12V 1A 15V 0.8A 3.3V 2.6A 5V 2A 12V 1A 15V 0.8A
Output Power 8.58W 10W 10.8W 10.5W 8.58W 10W 12W 8.58W 10W 12W 8.58W 10W 12W
Output Voltage Adj Range Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet Refer to datasheet
Operating Temp (°C) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating) -40 to +85℃, 20 - 95%RH (Non condensing) (Required Derating)
Cooling Method Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air Convection/Forced air
Dimensions (W x H x D) 45.2x29.3x9.15mm 45.2x29.3x9.15mm 45.2x29.3x9.15mm 45.2x29.3x9.15mm 45.2x29.3x9.15mm 45.2x29.3x9.15mm
Safety Agency Approvals UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1 UL60950-1, C-UL, EN62368-1
Technical Data SUTS10053R3 SUTS100505 SUTS100512 SUTS100515 SUTS10123R3 SUTS101205 SUTS101212 SUTS101215 SUTS10243R3 SUTS102405 SUTS102412 SUTS102415 SUTS10483R3 SUTS104805 SUTS104812 SUTS104815
Performance Data
EMC Data
Expected Life N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
MTBF
Reliability Data