Loading...
 

LCA15S

Discontinued

Discontinuation is announced in May 2019 and orders will be accepted until 20th April 2020.  For alternative open frame products, please see Open Frame AC-DC products.

Options

(For detailed information, please refer to the instruction manual)

  C: with Coating
  G: Low leakage current
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option.
string(535) "

LC(1)  A(2)  15(3)  S(4)  -  5(5)  -  (6)  

(1) Series name
(2) 100/120V input
(3) Output wattage
(4) Single output
(5) Output voltage
(6) Optional *
  C: with Coating
  G: Low leakage current
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option."

Product Data

  • Datasheet
  • Instruction Manual
  • Accessories
  • Glossary of Technical Terms

Drawings

Safety Certificates

  • Safety Approvals

LC(1)  A(2)  15(3)  S(4)  -  5(5)  -  (6)  

(1) Series name
(2) 100/120V input
(3) Output wattage
(4) Single output
(5) Output voltage
(6) Optional *
  C: with Coating
  G: Low leakage current
  Y: with Potentiometer
*Please contact us about safety approvals for the model with option.
Basic Specification LCA15S-5 LCA15S-12 LCA15S-15 LCA15S-24
  Check Stock Check Stock Check Stock Check Stock
Input Voltage Range AC85 - 132V 1Φ or DC110 - 170V AC85 - 132V 1Φ or DC110 - 170V
Output Voltage / Current 5V 3A 12V 1.3A 15V 1A 24V 0.7A
Output Power 15W 15.6W 15W 16.8W
Output Voltage Adj Range Refer to datasheet Refer to datasheet
Operating Temp (°C) -10 to +60℃, 20 - 90%RH (Non condensing) * -10 to +60℃, 20 - 90%RH (Non condensing) *
Cooling Method Convection Convection
Dimensions (W x H x D) 50x17x115mm 50x17x115mm
Safety Agency Approvals UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN UL60950-1, CSA C22.2 No.60950-1 Complies with DEN-AN
Technical Data LCA15S-5 LCA15S-12 LCA15S-15 LCA15S-24
Performance Data
EMC Data On request On request On request On request
Expected Life
MTBF
Reliability Data