NRND
Options
SNDH(1) S(2) 250(3) B(4) 05(5) - □(6)
(1) Series name(2) Single output
(3) Output wattage
(4) B: DC200V - 400V
(5) Output voltage
(6) Optional
C: with Coating
R: with a function not to need external power source
Basic Specification | SNDHS250B03 | SNDHS250B05 | SNDHS250B07 | SNDHS250B12 | SNDHS250B15 | SNDHS250B24 | SNDHS250B28 | SNDHS250B48 |
---|---|---|---|---|---|---|---|---|
Check Stock | Check Stock | Check Stock | Check Stock | Check Stock | Check Stock | Check Stock | Check Stock | |
Input Voltage Range | DC200 - 400V | DC200 - 400V | DC200 - 400V | |||||
Output Voltage / Current | 3.3V 50A | 5V 50A | 7.5V 33A | 12V 21A | 15V 16.5A | 24V 10.5A | 28V 9.0A | 48V 5.2A |
Output Power | 165.0W | 250.0W | 247.5W | 252.0W | 247.5W | 252.0W | 249.6W | |
Output Voltage Adj Range | 2.97 - 3.63V | 4.50 - 5.50V | 6.75 - 8.25V | 10.80 - 13.20V | 13.50 - 16.50V | 21.60 - 26.40V | 25.20 - 30.80V | 43.20 - 52.80V |
Operating Temp (°C) | -20 to +95℃ (Aluminum base plate of the power module) , 20 - 95%RH (Non condensing) * | -20 to +95℃ (Aluminum base plate of the power module) , 20 - 95%RH (Non condensing) * | -20 to +95℃ (Aluminum base plate of the power module) , 20 - 95%RH (Non condensing) * | |||||
Cooling Method | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) | Conduction cooling (e.g. heat radiation from the aluminum base plate to the attached heat sink) | |||||
Dimensions (W x H x D) | 74.2x44.5x127mm | 74.2x44.5x127mm | 74.2x44.5x127mm | |||||
Safety Agency Approvals | UL60950-1, C-UL, EN62368-1 | UL60950-1, C-UL, EN62368-1 | UL60950-1, C-UL, EN62368-1 | |||||
Technical Data | SNDHS250B03 | SNDHS250B05 | SNDHS250B07 | SNDHS250B12 | SNDHS250B15 | SNDHS250B24 | SNDHS250B28 | SNDHS250B48 |
Performance Data | ||||||||
EMC Data | ||||||||
Expected Life | ||||||||
MTBF | ||||||||
Reliability Data |