Loading...
 

UMA60F

Key Product Features

• For medical electric equipment
• Medical Isolation Grade 2MOPP
• 4kV isolation
• Suitable for BF application
• Low leakage current
• 2"× 3" standard footprint
• Universal input (AC85 - 264V, Derating is required)

Technical Features

  • Leakage Current <0.5mA

Options

(For detailed information, please refer to the instruction manual)

UM(1)  A(2)  60(3)  F(4)  -  (5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
  E: IEC Class II
  T: Terminal block
  SN: with Chassis & cover
  Y: with Potentiometer
string(506) "

UM(1)  A(2)  60(3)  F(4)  -  (5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
  E: IEC Class II
  T: Terminal block
  SN: with Chassis & cover
  Y: with Potentiometer"

Product Data

  • Datasheet
  • Instruction Manual
  • Glossary of Technical Terms

Drawings

  • CAD Data (DXF)
  • 3D CAD Data (STEP)
    • Standard model
    • SN: with Chassis and cover
  • 3D CAD Data (IGES)
    • Standard model
    • SN: with Chassis and cover

Safety Certificates

  • Safety Approvals
  • EU Declaration of Conformity
  • UK Declaration of Conformity

UM(1)  A(2)  60(3)  F(4)  -  (5)  -  (6)  

(1) Series name
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
(6) Option
  E: IEC Class II
  T: Terminal block
  SN: with Chassis & cover
  Y: with Potentiometer
Basic Specification UMA60F-5 UMA60F-7R5 UMA60F-12 UMA60F-15 UMA60F-24 UMA60F-36 UMA60F-48
  Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock Check Stock
Input Voltage Range AC85 ~ 264V 1Φ AC85 ~ 264V 1Φ AC85 ~ 264V 1Φ
Output Voltage / Current 5V 6A 7.5V 5.5A 12V 4.5A 15V 3.5A 24V 2.5A 36V 1.7A 48V 1.25A
Output Power 30W 41.25W 54W 52.5W 60W 61.2W 60W
Output Voltage Adj Range Refer to datasheet Refer to datasheet Refer to datasheet
Operating Temp (°C) -20 to +70℃ (Required to Derating) , 20 - 90%RH (Non condensing) -20 to +70℃ (Required to Derating) , 20 - 90%RH (Non condensing) -20 to +70℃ (Required to Derating) , 20 - 90%RH (Non condensing)
Cooling Method Convection Convection Convection
Dimensions (W x H x D) 50.8x24.2x76.2mm 50.8x24.2x76.2mm 50.8x24.2x76.2mm
Safety Agency Approvals ANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, complies with EN60335-1 ANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, complies with EN60335-1 ANSI/AAMI ES60601-1, EN60601-1 3rd, C-UL (equivalent to CAN/CSA-C22.2 No.60601-1), UL62368-1, C-UL (equivalent to CAN/CSA-C22.2 No.62368-1), EN62368-1, complies with EN60335-1
Technical Data UMA60F-5 UMA60F-7R5 UMA60F-12 UMA60F-15 UMA60F-24 UMA60F-36 UMA60F-48
Performance Data
EMC Data
Expected Life
MTBF
Reliability Data